Vitatron G20 SR and G70 DR pacemakers

Vitatron is a pacemaker brand of the Medtronic group based in Maastricht, the Netherlands. Its G-series has two models: the single-chamber G20 SR (G20A2) and the dual-chamber G70 DR (G70A2). Both are MRI SureScan: with SureScan leads they allow full-body 1.5 T and 3 T MRI. The price depends on the model, the leads and the quantity.

  • G20A2 single-chamber
  • G70A2 dual-chamber
  • IS-1
  • 1.5 T and 3 T MRI

Updated: 20 November 2026

Models and specifications

Vitatron G-series per the manufacturer's spec sheets
ModelTypeSize (H × W × D)WeightVolumeBatteryEstimated longevity
G20 SR (G20A2)Single-chamber, rate-responsive40.2 × 42.9 × 7.5 mm21.5 g9.7 ccLithium-iodine, 0.91 Ah10.4 years at 50% pacing; 9.6 years at 100%
G70 DR (G70A2)Dual-chamber DDDR44.7 × 47.9 × 7.5 mm27.1 g12.1 ccLithium-iodine, 1.3 Ah11.4 years at 50% pacing; 10.2 years at 100%

Longevity is calculated at 60 bpm, 0.4 ms and 500 Ω, at 2.0 V on the G20 and 1.5 V and 2.0 V on the G70. Both models use an IS-1 bipolar or unipolar connector. They are programmed with Medtronic programmers and Vitatron software; programmers from other brands are not compatible.

Earlier non-SureScan versions exist, G20A1 and G70A1. When asking for a quote, give the full model number.

Main features

  • Rate response with an activity sensor, which raises or lowers the rate with the patient's effort, with automatic profile adjustment (Rate Profile Optimization).
  • Ventricular Output Management, and on the G70 also Atrial Output Management: automatic capture tests that adjust the output amplitude.
  • Reduced VP+ and Sinus Preference, on the G70 DR: favour the patient's own conduction and rhythm to reduce unnecessary ventricular pacing.
  • Atrial therapies on the G70 DR: mode switch, Atrial Preference Pacing and post mode switch overdrive pacing (PMOP).
  • Sensing Assurance and Lead Monitor, which watch sensing and the leads and can switch polarity automatically.
  • Cardiac Dashboard II and CardioTrend diagnostics, with up to 6 months of daily data.

MRI and SureScan leads

For an MRI scan, the patient needs a complete SureScan system: the G20A2 or G70A2 pacemaker and Medtronic SureScan leads. The spec sheets state full-body 1.5 T and 3 T MRI. Before the scan, the pacemaker is programmed to SureScan mode.

MRI SureScan leads listed by Medtronic
SureScan leadFixationNote
CapSureFix Novus MRI 5076Active (helix)MR Conditional from 35 to 85 cm; the 49, 98 and 110 cm lengths are not. 7 F introducer without guidewire.
CapSureFix Novus MRI 4076Active (helix)Only certain lengths are MR Conditional
CapSure Sense MRI 4074 / 4574Passive (tines)Only certain lengths are MR Conditional
CapSureFix MRI 5086MRIActive (helix)Only certain lengths are MR Conditional
SelectSecure MRI SureScan 3830Active (helix)Implanted with a delivery catheter

Check each lead's manual for which lengths are MR Conditional. More about the system in generator and leads.

Vitatron pacemaker price

The price depends on:

  • The model: single-chamber G20 SR or dual-chamber G70 DR, and whether it is the SureScan version.
  • The SureScan leads: one or two, and their length.
  • The introducers and implant accessories.
  • The quantity: the unit price falls with volume.

Volume pricing

The unit price falls as the quantity grows. That is why we do not publish a single price: we calculate it from the model, the quantity and how often you buy.

Get a volume quote

Unit price (illustrative)

The doctor makes the choice

The pacemaker type, brand and programming are decided by the cardiologist or electrophysiologist according to each patient's diagnosis. This page informs about options and prices and does not replace a medical assessment.

How a pacemaker is chosen

Frequently asked questions

What is the price of a Vitatron pacemaker?

It depends on whether it is the single-chamber G20 SR or the dual-chamber G70 DR, the SureScan leads that go with it and the quantity. Send us the model and number of units for a quote.

Is Vitatron part of Medtronic?

Yes. Vitatron is a Medtronic group brand based in Maastricht, the Netherlands. Its pacemakers are programmed with Medtronic programmers.

What is the difference between the Vitatron G20 and G70?

The G20 SR is single-chamber: it uses one lead and paces one chamber. The G70 DR is dual-chamber, uses two leads and adds features to reduce ventricular pacing plus atrial therapies. The G70 is slightly larger (12.1 cc versus 9.7 cc) and its battery has more capacity.

Do the Vitatron G20 and G70 allow MRI?

Yes, the G20A2 and G70A2 versions are MRI SureScan: with SureScan leads they allow full-body 1.5 T and 3 T MRI, following the manufacturer's conditions. The earlier G20A1 and G70A1 versions are not SureScan.

How long does a Vitatron G70 battery last?

The spec sheet estimates 11.4 years at 50% pacing and 10.2 years at 100%, under the manufacturer's reference conditions. Real battery life depends on programming.

Request a quote

Tell us the brand, type and quantity. We reply within 24 hours with the unit price based on volume, availability and delivery time.

  • Unit price based on the total quantity.
  • Original manufacturer products.
  • Availability subject to each model's health registration in Mexico.