Pacemaker types
There are five main types of cardiac pacing devices: single-chamber, dual-chamber and leadless pacemakers, CRT pacemakers (CRT-P) and implantable defibrillators (ICD). They differ in how many heart chambers they pace, how many leads they use and what therapy they give.
Updated: 17 November 2026
| Type | Leads | What it does | Examples |
|---|---|---|---|
| Single-chamber (SR) | 1, in the atrium or ventricle | Paces one chamber. Usual mode VVI(R) or AAI(R). | Azure SR, Endurity Core SR, ALTRUA 2 SR |
| Dual-chamber (DR) | 2, in the atrium and ventricle | Keeps the atrium-ventricle sequence. Usual mode DDD(R). | Azure DR, Assurity MRI DR, Amvia Sky DR-T |
| Leadless | None | A capsule inside the heart, with no pocket under the skin. | Micra AV2, Micra VR2, AVEIR |
| CRT pacemaker (CRT-P) | 3, one of them in the left ventricle | Coordinates both ventricles in some cases of heart failure. | Percepta, Quadra Allure, VISIONIST |
| Implantable defibrillator (ICD) | 1 to 3 | Detects dangerous ventricular arrhythmias and treats them with pacing or a shock. | Cobalt, Crome, Acticor |
Single or dual-chamber: the difference
A single-chamber pacemaker has one lead, placed in the atrium or, more often, the right ventricle. A dual-chamber pacemaker has two: one in the atrium and one in the ventricle, and it times when each chamber contracts. That timing is called atrioventricular synchrony.
The doctor chooses the type based on the rhythm disorder. For the buyer, the practical difference is that a dual-chamber system needs two leads and its generator is slightly larger.
What VVI, AAI and DDD mean
Pacemaker modes are written with a three-to-five-letter code. The first four are the ones you will see on spec sheets and quotes:
| Letter | What it shows | Values |
|---|---|---|
| 1st | Chamber paced | A atrium · V ventricle · D both · O none |
| 2nd | Chamber sensed | A · V · D · O |
| 3rd | Response to sensing | I inhibit · T trigger · D both · O none |
| 4th | Rate modulation | R activity sensor on · O no sensor |
So VVI paces and senses the ventricle and holds back if there is a natural beat. DDDR works in both chambers, responds both ways and adapts the rate to physical activity. VDD, Micra AV2's mode, senses the atrium but paces only the ventricle.
The pacemaker type, brand and programming are decided by the cardiologist or electrophysiologist according to each patient's diagnosis. This page informs about options and prices and does not replace a medical assessment.
Frequently asked questions
How many types of pacemakers are there?
There are three types of pacemakers: single-chamber, dual-chamber and leadless. There are also CRT pacemakers (CRT-P), with three leads, and implantable defibrillators (ICD), which can also pace.
What does DDD mean on a pacemaker?
That the device paces and senses in both chambers (atrium and ventricle) and responds by inhibiting or triggering based on what it senses. With an R at the end, DDDR, it also adapts the rate to activity.
What is a three-chamber pacemaker?
It is the common name for a CRT pacemaker (CRT-P). It uses three leads: right atrium, right ventricle and left ventricle.
Request a quote
Tell us the brand, type and quantity. We reply within 24 hours with the unit price based on volume, availability and delivery time.
- Unit price based on the total quantity.
- Original manufacturer products.
- Availability subject to each model's health registration in Mexico.
Contact: cotizaciones@marcapasosprecio.mx